Cryogenics

One of our core services is cryogenic testing of materials, components, devices and complete instruments between 4 K and room temperature, supported by cryogenic systems that we design and build ourselves.

Cryogenic testing

We have built large-volume cryostats operating at 4 K, with working volumes up to 200 litres, as well as closed-cycle 3He-4He systems that reach 0.3 K.

Testing for space missions

  • ESA’s Ariel exoplanet mission: cryogenic testing of components is under way, under a subcontract from the Canadian Space Agency.
  • SPICA SAFARI: a 4 K post-dispersed polarizing FTS with a 0.3 K detector, and a tunable cryogenic far-infrared spectral line source and blackbody source.
  • Cryogenic FTS mechanisms: laser position metrology that dissipates no electrical power in the cold region (see Photonics).

More on our work for space missions is on the Spaceborne Astronomy page.

Cryogenic systems

For maximum sensitivity, detectors in the infrared/THz range require cryogenic cooling. Blue Sky Spectroscopy has extensive experience with design, construction and operation of liquid cryogen and cryogen-free cryostats and related technologies.

Cryostats

For laboratory applications, liquid cryogen-based detector systems offer advantages of lower initial cost, higher cooling capacity, and simpler vacuum design, whereas cryogen-free cryostats are simpler to use and cheaper in the long run. We can provide standard or custom dewar configurations with base temperatures down to 4K. We also have extensive experience with closed cycle 3He-4He refrigerators, which provide cooling to 0.3 K.

We are partnered with Celtic Terahertz Technology who provide turnkey detector and cryostat solutions. We have also produced custom cryostats with working volumes ranging from 1 cc at 60K to 200 l at 4K.

Liquid-cryogen cryostat with brass fittingsCryogenic detector system mounted in an electronics rack

Closed cycle Stirling refrigerators

Closed-cycle Stirling coolerIn systems where instrument size and maintenance are main concerns, we can provide integrated detector cooler assemblies (IDCAs) based on closed cycle refrigerators, with vacuum and cooler lifetimes measured in years.

Long hold time cryogenic dewars and IDCAs

Long hold time cryogenic dewarIn order to provide minimum operational requirements, care must be taken in the dewar design and construction to minimize thermal loading and maximize cryogen hold times. We can provide 4He systems with hold times measured in weeks. Hermetically sealed cryocooler-based systems require considerable care in the dewar design to achieve non-pumped lifetimes equal to the cryocooler MTF, with hold times measured in years.

Cryogenic thermometry (0.3 to 300 K)

Cryogenic temperature sensors beside a rulerUsing industry standard Lakeshore temperature sensors, our own low-cost calibrated sensors, or more exotic low temperature bolometers, we have extensive experience in the cryogenic thermometry required for instrument control, diagnostics, and characterization.

Please browse through our listing of products and capabilities, and contact us with your custom infrared instrumentation requirements.